low voltage (1000 V) https://batterystandards.info/ en IEC/EN 60664-3 https://batterystandards.info/standard/iecen-60664-3 <span class="field field--name-title field--type-string field--label-hidden">IEC/EN 60664-3</span> <span class="field field--name-uid field--type-entity-reference field--label-hidden"><span lang="" about="/user/1" typeof="schema:Person" property="schema:name" datatype="">chuck</span></span> <span class="field field--name-created field--type-created field--label-hidden">Thu, 05/27/2021 - 12:53</span> <div class="field field--name-field-link field--type-string field--label-above"> <div class="field__label">Link</div> <div class="field__item"><a target="_blank" href="https://webstore.iec.ch/webstore/webstore.nsf/Artnum_PK/44477">webstore.iec.ch/webstore/webstore.nsf/Artnum_PK/44477</a></div> </div> <div class="clearfix text-formatted field field--name-field-description field--type-text-long field--label-above"> <div class="field__label">Description</div> <div class="field__item"><p>Insulation coordination for equipment within low-voltage systems – Part 3: Use of coating, potting or moulding for protection against pollution</p> </div> </div> <div class="field field--name-field-application field--type-entity-reference field--label-above"> <div class="field__label">Application</div> <div class="field__items"> <div class="field__item"><a href="/tag/equipment" hreflang="en">equipment</a></div> </div> </div> <div class="field field--name-field-commission field--type-entity-reference field--label-above"> <div class="field__label">Commission</div> <div class="field__items"> <div class="field__item"><a href="/tag/iec-tc28" hreflang="en">IEC TC28</a></div> </div> </div> <div class="field field--name-field-editor field--type-entity-reference field--label-above"> <div class="field__label">Editor</div> <div class="field__items"> <div class="field__item"><a href="/tag/iec" hreflang="en">IEC</a></div> <div class="field__item"><a href="/tag/cenelec" hreflang="en"> CENELEC</a></div> </div> </div> <div class="field field--name-field-geography field--type-entity-reference field--label-above"> <div class="field__label">Geography</div> <div class="field__items"> <div class="field__item"><a href="/tag/world" hreflang="en">World</a></div> </div> </div> <div class="field field--name-field-objective field--type-entity-reference field--label-above"> <div class="field__label">Objective</div> <div class="field__items"> <div class="field__item"><a href="/tag/guidance" hreflang="en">guidance</a></div> </div> </div> <div class="field field--name-field-phase field--type-entity-reference field--label-above"> <div class="field__label">Phase</div> <div class="field__items"> <div class="field__item"><a href="/tag/all" hreflang="en">all</a></div> </div> </div> <div class="field field--name-field-processor field--type-entity-reference field--label-above"> <div class="field__label">Processor</div> <div class="field__items"> <div class="field__item"><a href="/taxonomy/term/95" hreflang="en">-</a></div> </div> </div> <div class="field field--name-field-target field--type-entity-reference field--label-above"> <div class="field__label">Target</div> <div class="field__items"> <div class="field__item"><a href="/tag/elinstallation" hreflang="en">el.installation</a></div> </div> </div> <div class="field field--name-field-type field--type-entity-reference field--label-above"> <div class="field__label">Type</div> <div class="field__items"> <div class="field__item"><a href="/tag/low-voltage-1000-v" hreflang="en">low voltage (1000 V)</a></div> </div> </div> <div class="field field--name-field-year field--type-integer field--label-above"> <div class="field__label">Year</div> <div class="field__item">2010</div> </div> <div class="clearfix text-formatted field field--name-field-scope field--type-text-long field--label-above"> <div class="field__label">Scope</div> <div class="field__item"><p>This part of IEC 60664 applies to assemblies protected against pollution by the use of coating, potting or moulding, thus allowing a reduction of clearance and creepage distances as described in Part 1 or Part 5. -- NOTE 1 When reference is made to Part 1 or Part 5, IEC 60664-1 or IEC 60664-5 are meant. -- This standard describes the requirements and test procedures for two methods of protection: – type 1 protection improves the microenvironment of the parts under the protection; – type 2 protection is considered to be similar to solid insulation. This standard also applies to all kinds of protected printed boards, including the surface of inner layers of multi-layer boards, substrates and similarly protected assemblies. In the case of multi-layer printed boards, the distances through an inner layer are covered by the requirements for solid insulation in Part 1. -- NOTE 2 Examples of substrates are hybrid integrated circuits and thick-film technology. -- This standard refers only to permanent protection. It does not cover assemblies that are subjected to mechanical adjustment or repair. -- The principles of this standard are applicable to functional, basic, supplementary and reinforced insulation.</p> </div> </div> Thu, 27 May 2021 10:53:36 +0000 chuck 528 at https://batterystandards.info IEC 60664-4 https://batterystandards.info/standard/iec-60664-4 <span class="field field--name-title field--type-string field--label-hidden">IEC 60664-4</span> <span class="field field--name-uid field--type-entity-reference field--label-hidden"><span lang="" about="/user/1" typeof="schema:Person" property="schema:name" datatype="">chuck</span></span> <span class="field field--name-created field--type-created field--label-hidden">Thu, 05/27/2021 - 12:53</span> <div class="field field--name-field-link field--type-string field--label-above"> <div class="field__label">Link</div> <div class="field__item"><a target="_blank" href="https://webstore.iec.ch/preview/info_iec60664-4{ed2.0}b.pdf">webstore.iec.ch/preview/info_iec60664-4{ed2.0}b.pdf</a></div> </div> <div class="clearfix text-formatted field field--name-field-description field--type-text-long field--label-above"> <div class="field__label">Description</div> <div class="field__item"><p>Insulation coordination for equipment within low-voltage systems – Part 4: Consideration of high-frequency voltage stress</p> </div> </div> <div class="field field--name-field-application field--type-entity-reference field--label-above"> <div class="field__label">Application</div> <div class="field__items"> <div class="field__item"><a href="/tag/equipment" hreflang="en">equipment</a></div> </div> </div> <div class="field field--name-field-commission field--type-entity-reference field--label-above"> <div class="field__label">Commission</div> <div class="field__items"> <div class="field__item"><a href="/tag/iec-tc28" hreflang="en">IEC TC28</a></div> </div> </div> <div class="field field--name-field-editor field--type-entity-reference field--label-above"> <div class="field__label">Editor</div> <div class="field__items"> <div class="field__item"><a href="/tag/iec" hreflang="en">IEC</a></div> </div> </div> <div class="field field--name-field-geography field--type-entity-reference field--label-above"> <div class="field__label">Geography</div> <div class="field__items"> <div class="field__item"><a href="/tag/world" hreflang="en">World</a></div> </div> </div> <div class="field field--name-field-objective field--type-entity-reference field--label-above"> <div class="field__label">Objective</div> <div class="field__items"> <div class="field__item"><a href="/tag/guidance" hreflang="en">guidance</a></div> </div> </div> <div class="field field--name-field-phase field--type-entity-reference field--label-above"> <div class="field__label">Phase</div> <div class="field__items"> <div class="field__item"><a href="/tag/all" hreflang="en">all</a></div> </div> </div> <div class="field field--name-field-processor field--type-entity-reference field--label-above"> <div class="field__label">Processor</div> <div class="field__items"> <div class="field__item"><a href="/taxonomy/term/95" hreflang="en">-</a></div> </div> </div> <div class="field field--name-field-target field--type-entity-reference field--label-above"> <div class="field__label">Target</div> <div class="field__items"> <div class="field__item"><a href="/tag/elinstallation" hreflang="en">el.installation</a></div> </div> </div> <div class="field field--name-field-type field--type-entity-reference field--label-above"> <div class="field__label">Type</div> <div class="field__items"> <div class="field__item"><a href="/tag/low-voltage-1000-v" hreflang="en">low voltage (1000 V)</a></div> </div> </div> <div class="field field--name-field-year field--type-integer field--label-above"> <div class="field__label">Year</div> <div class="field__item">1997</div> </div> <div class="clearfix text-formatted field field--name-field-scope field--type-text-long field--label-above"> <div class="field__label">Scope</div> <div class="field__item"><p>This part of IEC 60664 deals with basic, supplementary and reinforced insulation subjected to high-frequency voltage stress within low-voltage equipment. The dimensioning values directly apply for basic insulation; for reinforced insulation additional requirements apply according to Part 1. It is applicable for the dimensioning of clearances, creepage distances and solid insulation stressed by any type of periodic voltages with a fundamental frequency above 30 kHz and up to 10 MHz. -- This part of IEC 60664 can only be used together with IEC 60664-1 or with IEC 60664-5 (in this standard called Part 1 or Part 5). By using Part 1 or Part 5 together with this part the frequency limit of Part 1 or Part 5 is extended to frequencies higher than 30 kHz. This part also applies to Part 3 for frequencies greater than 30 kHz and protection of type 1. For type 2 protection this question is under consideration. -- NOTE 1 Dimensioning values for frequencies above 10 MHz are under consideration. NOTE 2 This standard does not consider the high-frequency emission to the mains. In normal use of equipment, it is assumed that the interference of high-frequency voltages emitted to the mains is negligible with respect to insulation stress. Therefore it is not necessary to take it into account. It applies to equipment for use up to 2 000 m above sea level having a rated voltage up to a.c. 1 000 V. -- It specifies the requirements for clearances, creepage distances and solid insulation for equipment based upon their performance criteria. lt includes methods of electric testing with respect to insulation coordination.</p> </div> </div> Thu, 27 May 2021 10:53:36 +0000 chuck 527 at https://batterystandards.info